Home

GWF METER

GWF LOGO

Installation and maintenance
Can be installed in any position from horizontal to vertical Simple exchange of the meters on site. The heavyweight monopipe adapter remains in the pipeline.
The disconnection of the meter and monopipe adapter allows a strain-free meter installation

High Pressure LP Gas Flow Meters       ( GWF )

Mounting and maintenance:

  ? Mounting / dismounting of the meter element possible     without disconnecting the monopipe fitting
  ? The monopipe fitting remaining in the pipe network enables     mounting/dismounting of the meter element without tension     from the pipe network
  ? Can be installed in any position from horizonatal to vertical     (turbine axis not suspended and roller counter axle always     horizontal

Technical characteristics
  ? Principle of velocity measurement
  ? For internal measurement (without verification)
  ? Sizes Q16 upto Q400 for flow.
  ? Connections Dn 40, 50, 80 and 100
  
? Different Q-sizes per nominal width :
    -DN 40 : Q 16 upto Q 65
    -DN 50 : Q 16 upto Q 100
    -DN 80 : Q 65 upto Q 250
    -DN 100 : Q 100 upto Q 400
  ? Operational Pressure max. 6 bar
  ? Meter without monopipe fitting can be calibrated
 
? Pressure extraction connection inside the meter

 

  ? Counting device is in a gas free space
? Low starting value
  ? High measurement stability and operational security due to     High-quality, wear resistant componenets; self lubricating     ball   bearings
  ? Designed for simple servicing (measurement-cartridge     principle)
  ? Standard integrated flow strainer
  ? Short straight inlet lengths (2XDN)
  ? Operation temperature range :
    -Gas temperature
    -10 C upto +60 C
    -Ambient temperature
    -20 C upto + 70 C

Options:
  ? Over-run brake :
Mechanical over-run brake without measuring range restriction for intermittent operation
  ? Pulse generators :
- 2 X LF-IPG, 1 X can be retrofitted without breaking the manufacturing seal
- MF-IPG
- HF-IPG
  ? Temperature sensor pockets in the monopipe fitting

 

Norms:
Developed and produced according to Quality Standard ISO 9001