Technical characteristics ? Principle of velocity measurement ? For internal measurement (without verification) ? Sizes Q16 upto Q400 for flow. ? Connections Dn 40, 50, 80 and 100 ? Different Q-sizes per nominal width : -DN 40 : Q 16 upto Q 65 -DN 50 : Q 16 upto Q 100 -DN 80 : Q 65 upto Q 250 -DN 100 : Q 100 upto Q 400 ? Operational Pressure max. 6 bar ? Meter without monopipe fitting can be calibrated ? Pressure extraction connection inside the meter
|
? Counting device is in a gas free space ? Low starting value ? High measurement stability and operational security due to High-quality, wear resistant componenets; self lubricating ball bearings ? Designed for simple servicing (measurement-cartridge principle) ? Standard integrated flow strainer ? Short straight inlet lengths (2XDN) ? Operation temperature range : -Gas temperature -10 C upto +60 C -Ambient temperature -20 C upto + 70 C
|
|
Options: ? Over-run brake : Mechanical over-run brake without measuring range restriction for intermittent operation ? Pulse generators : - 2 X LF-IPG, 1 X can be retrofitted without breaking the manufacturing seal - MF-IPG - HF-IPG ? Temperature sensor pockets in the monopipe fitting
|
Norms: Developed and produced according to Quality Standard ISO 9001
|